Wells gardner monitor repair. Oct 29, 2011 · Where do I start on trying to repair.



Wells gardner monitor repair $9. PO Box 455 Missoula, MT 59806 Jul 7, 2009 · This is a D9200 monitor, sometimes called "That Damn D9200" by monitor repair techs. -We can also fully repair any & all power supply's. BEST quality, low ESR & longest life capacitors included www. A “hybrid” monitor, it shares the characteristics of both an arcade and a PC monitor. 2200 Publicly Traded (AMEX: WGA), www. Part Number: 49-1153-00. “Mega Deluxe Cap Kits” BEST quality, low ESR longest life capacitors Thank you to everyone who has been supporting our channel! If you use the link below before you purchase anything on Amazon, we get a royalty for sending yo Wells Gardner k7500 medium resolution monitor. “ Wells-Gardner Announces Distribution Agreement with Pacific Electronics, ” PR Newswire, January 6, 2000. Upgraded it to an LV2000, replaced Caps, and Diodes D100-D104. Cap kits, flybacks and other parts are available online, but again don’t mistake this for a K7000! Symptoms were, well, it died! No high voltage or neck glow. Mar 19, 2016 · Wells Gardner 6100 repair log success! 25v B+ issue, blown flyback Wells Gardner WG6100 repair (weeks of reading, component testing, and cap kits for every board in the Cabinet and monitor): Star Wars Arcade Stand Up HV model #P316 Deflection model #P327 A LV2000 kit was previously installed on deflection board by previous owner. The picture is a representation of the cap kit you will receive. This kit is for the D9204 27″ monitor and the D9205 33″ monitor (27D9204, 33D9205, WGM2792 and WGM3392 which can have P857 and 025A1569-001E on the PCB but make sure to check your specific model with the NOTE below as both models can have this on the PCB. Wells Gardner 25″/27″ Chassis (LINK COMING SOON) Wells Gardner P719 Neck Board. These large 39″ monitors are found in the newer games such as star trek voyager and others. You will be contacted for your approval if your flyback is more expensive. Includes bench testing on a a compatible CRT tube and y A little FYI I've been having problems with a couple bartop monitors (Ceronix 1493s). Remove flyback and neck socket to the lesser detriment of your monitor. Step 2 - Print the RMA and put it in a box with the items for repair CT8584 / TFT014000-1502 / TFT0140001502 / 2ATFT1415-002 / 2ATFT1415002 Wells Gardner K7203 13 inch and 19 inch P819 / P859 monitor Flyback transformer. “Mega Deluxe Cap Kits” 23 Capacitors including the Bi-Polar in this kit with great instructions. Wells Gardner 009A-2838-001A New Width Coil. There are a few exceptions, which are more than $65 for rare flybacks. . The inductance value of the coil is 45µH – 250µH. Over 130 Cap Kits for Monitor Repair Joe@syracusesemiconductors. Used on Wells Gardner 25 inch K7000 P538 25" monitor chassis. However, it does not contain an audio amplifier like the Sanyo had so you would need to provide some sort of amplifier for sound. Save up to 15% when you May 23, 2024 · I've been repairing and tidying up a Midway Space Invaders cocktail/tabletop machine and apart from addressing some sound faults on the game board, I changed out the electrolytic capacitors on the 19 inch Wells Gardner monitor. Age, humidity, and temperature will cause the value of electrolytic capacitors to I repair an arcade monitor from a Warp Warp arcade game. Oct 29, 2011 · Where do I start on trying to repair Forums. PO Box 455 Missoula, MT 59806 May 28, 2015 · Question from Todd: I’m helping a friend with his arcade cabinet and doing all the legwork. removal of the chassis assembly varies depending if your monitor frame is horizontal or vertical. Repairs take 2-4 business days after receiving your faulty circuit board. All of our Cap Kits / Get Well Kits include a sticker so you can place it on the monitor to help you keep track of the work you did and when it 053X0632-001 Flyback Transformer. “Mega Deluxe Cap Kits” P299 and P300 boards. jjhudgins Wells Gardner U5000 Series arcade Monitor Cap Kit 105C 100% Nichicon Capacitors. Orion # A34JLL40X25. 65. 82 mm HORIZONAL SCAN Frequency: Mode 1: 15. I can hear the "bzzzzt" on the monitor when powering up but dead monitor with no picture and no neck glow. Adjust B+ at VR501. 15000 Service Manual Monitor Specifications CRT 25", 27" or 33" diagonal measure. 07. 3 volts. This is for both the 13″ and 19″ chassis PD137700 and PD197700. Wells Gardner K7300 Series arcade Monitor Cap Kit 105C 100% Nichicon Capacitors. Capable of displaying nearly all arcade display modes, it is also capable of displaying standard CGA, EGA, VGA, and (unofficially) SVGA PC modes. inductance value of coil is 20µH - 100µH. to 18. Kit NOW INCLUDES the 560uf 200 Volt Snap in Filter Cap. Wells Gardner D9200 / D9204 / D9205 27″ & 33″ Series arcade Monitor Cap Kit 105C 100% Nichicon Capacitors. vertical configurations I’ve found it easiest to unbolt the entire bottom Wells-Gardner Monitor Repair Kits Available for the following Wells-Gardner Monitors: D9200: 27″ Digital Multiscan Color Monitor D9400: 27″ Digital Multiscan Color Monitor K3100: 13″ and 19″ Color Monitors K4500: 25″ Color Monitor K4600: 19″ Color Monitor K4800: 13″ Color Monitor K4900: 19″ Color Monitor K6100: 19″ X/Y Color Monitor K7000: 13″, 19″ and 25″ Color […] Jan 21, 2025 · Wells Gardner K4600 Series arcade monitor Cap Kit 105C and 100% Nichicon Capacitors. We believe each kit is accurate. Jun 12, 2024 · Part Number: Wells Gardner D9400 Arcade Cap Kit / Get Well Kit for Monitor Repair. It can be used for all of the games you listed. These are found on many arcade game monitor chassis. The original pots were rated at 0. Wells-Gardner produced a large screen medium resolution follow-up to their maligned K8000 with the U5000. -We perform a full rebuild/repair on all monitor chassis boards we receive for repair to insure long time full function. Electrohome G07 – Set to 120vdc – Check with black meter lead on chassis ground and red lead on the white wire closest to the tube on the ceramic resistor that is Each monitor design has a slightly different electrical characteristic and tube shape that will cause games designed for use with the Amplifone to bulge out around the edges (a defect known as "barreling") when using a Wells-Gardner and similarly will cause games designed for use with the Wells-Gardner monitor to cleave inward around the outer Wells Gardner V1000 Series arcade Monitor C101 Multi Cap B+ Filter Can Kit 105C 100% Nichicon Capacitors. Wells-Gardner Technologies, Inc 16W281 S. Its recommend to install a new Atari Big Blue Transformer cap and Audio Regulator power supply rebuild kit. Some of our stock is NOS original wells gardner flybacks so you could get either depending what we pull and both work interchangeably. arcadepartsandrepair. This Wells Gardner U5000 Monitor Chassis Parts Or Repair is the perfect item for collectors and enthusiasts of arcade gaming. Step 2 - Print the RMA and put it in a box with the items for repair Rebuilt the monitor. The new flyback has two red wires and the smaller diameter red wire goes to the single pin post on the neck board and the larger diameter red wire goes to the white Wells-Gardner Electronics Corporation • 9500 West 55th Street, Suite A • McCook, IL 60525-3605 • (800) 336-6630 Wells-Gardner Electronics Corporation • 9500 West 55th Street, Suite A • McCook, IL 60525-3605 • (800) 336-6630 Location Adjustment Method Function Brightness Contrast H. com : WELLS GARDNER MONITORS - Buttons / Switches Currency and Coin Handling Speakers Electrical T-Molding Nuts & Bolts / Fasteners Labels CLEARANCE ITEMS P C B Board Cap Kits Cleaning / Maintance Tools Foosball Pinball Parts Video Converters Billiards Trackballs Assemblies & Parts Dance Machine Parts Monitor Cap Kits - video Shuffleboard Pucks/Parts Locks /Security PC & MAME Shirts:https://teespring. check tr351-tr354. The K8000 was known for being 25″ medium resolution or 33″ standard resolution, but other variations may have existed, albeit undocumented. 0 kHz. $130. Wells Gardner 009A-2812-004 New Width Coil. Games like Moon Patrol or Double Dragon are displayed in a square orientation and the range of the width coil probably won’t be enough to fill out the screen. 2793 High Resolution Solutions ® Jun 22, 2019 · Wells Gardner K4600 Series arcade monitor Cap Kit 105C and 100% Nichicon Capacitors. 6630 Fax: 630. May 25, 2013 · yes, the C3688 is supposed to be a more robust part. wellsgardner. if you have another working k4600 monitor, swap the sync boards. 468. Jun 12, 2024 · Part Number: Wells Gardner 19V2000 Arcade Cap Kit / Get Well Kit for Monitor Repair. If the power button is switched on the game it makes a click over and over and the monitor is blank. We replace all electrolytic capacitors and repair common issues with this monitor such as reflowing cold solder joints and inspection of components. Jun 5, 2018 · REPAIR of a 27" D9200 Arcade Monitor made by Wells Gardner CRT tri sync. 229-5375 Email: Click here to email us Wells Gardner K6100/K6400 Monitor rebuild kit. patreon. 15W pots in them which are very much underrated. This neck board is used on all of the Wells Gardner monitors on this page. 60525-3605 (708) 290-2100 Revision ORG/E11004 D9400 User manual Date 2-10-06 Checked / Date Approved / Date Lee Sutton 2/10/06 Lee Sutton 2/10/06 Width coil original wells gardner brand new. In return, I expect to see the following from Wells Gardner: 1) Some more realistic troubleshooting documents available from Wells Gardner. K7400 Dim Picture Black and White not R811 but Open R310 Repair Log. This kit is for the D9202 27″ monitor and the D9202 33″ monitor WGM2792 and WGM3392 which can have P857 and 025A1569-001E on the PCB but make sure to check your specific model with the NOTE below as both models can have this on the PCB. Wells Gardner 19V2000 Series arcade monitor Cap Kit 105C 100% Nichicon capacitors. Monitor Flybacks. Download WELLS GARDNER D9200 27 DIGITAL MONITOR SCH service manual & repair info for electronics experts Service manuals, schematics, eproms for electrical technicians This site helps you to save the Earth from electronic waste! Please contact Wells-Gardner for updated specifications. Polished faceplate with P22 phosphor. and may other models and sizes of arcade monitor chassis. Opens in a new window or tab. The numbers I can find on it are as follows: -Sticker on the flyback coil shield WG 2223710 -Sticker on top 5775 Ten Mile Road, Warren, MI 48091 Tel: 800. Solution: Replace R760 and Q708. net), or www. Z500 ZENER DIODE 12V 5% 1. Home / Monitor Chassis Pictures / Wells Gardner K7400 Top. com) Jan 1, 2022 · Wells Gardner U2000 25"/27" Standard Resolution, Wells Gardner U5000 25"/27" Dual Resolution: Repair of monitor board to working, full recap, and solder reflow. The nichicon axial capacitors are 85c and all radial capacitors in the kit are nichicon 105c. I. I’ve checked continuity on the … Jul 14, 2010 · Also note that from a functionality standpoint, all of these monitors are electrically compatible. K7500 SERIES REPAIR GUIDE 9500 W. Position Extra Super Caution: Do not attempt to physically remove the width coil to work on this monitor, as this is a fragile part and you will undoubtedly break it trying to pry it from the clips. 55th Street, Suite A McCook, IL 60525 Tel: 708-290-2100 • 800-336-6630 Fax: 708-290-2200 www. 336. We can repair your Wells Gardner model 19K7901 in our facility. com/stores/mattymos-arcadeBecome a Patronhttps://www. I have a another tube but I know these WGM2574 were a short run. You can run a black and white vector game on a color monitor. 64. There is good info here, but I apologize for the sound. Our kits have some of the BEST quality, low ESR, and longest life capacitors included. Service and repair your broken Wells Gardner part. How Do Wells-Gardner and Amplifone Differ? While this document will deal specifically with the Wells-Gardner 19K6100, it is important to note that Atari used two different (but pinout compatible) versions of the color vector monitor. it is recommended to replace all electrolytic capicitors. Reproduction Wells Gardner K7000 monitor chassis Bare Neck PCB kit using the CR31 Skinny Neck Socket, P456 type, (PC1034). Sprayway 848 Plastic Cleaner. Color monitor. Let our skilled technicians get your Wells Gardner back in operation quickly. does the monitor work? ok yes measure the voltage no at the metal case of tr601. Oct 28, 2018 · Wells Gardner U5000 Series Monitor Cap Kit 105C-Arcade Parts and Repair Wells Gardner U5000 Series arcade Monitor Cap Kit 105C 100% Nichicon Capacitors. $18. On the Wells-Gardner K4900, you can alter the width with different value caps at the C365 position. Troubleshooting flowcharts that consist of MORE than the most basic problems solved by replacing a large number of components. It was totally dead but replaced the power supply and faulty switch and got it to start up. 5W 066X0040-046 TO-3 Package. com Wells Gardner K7200 Series arcade monitor Cap Kit 105C 100% Nichicon Capacitors “Mega Deluxe Cap Kits” and the Kit includes 24 Capacitors which includes 3 Bi-Polar caps. Oct 13, 2022 · The monitor chassis is a Wells Gardner 19K7901. New Pictures are added often!!!! We hope these pictures will help you identify your chassis and help identification of all parts on PCB. Kildare Avenue • Chicago, Illinois 60639 • (800) 336-6630 REPLACEMENT PARTS LIST Main, Neck & Control PCB Assembly Parts List DIODES DESIGNATION DESCRIPTION PART NO. All of our Cap Kits / Get Well Kits include a sticker so you can place it on the monitor to help you keep track of the work you did and when My purpose is to aid in the repair and preservation of video arcade, gaming and bowling alley equipment by means of specializing in monitor chassis board repair. Symptoms are when the machine is powered on, the proper display flashes quickly on then goes away. Weight. Wells-Gardner Electronics Corporation • 2701 N. 75 =======================================================Everything listed from Amazon that I actually use and recommend :)==================================== Wells Gardner K7000 Series Flyback Transformer 053X0528-001 this works for the 13″, 19″ and 25″ standard resolution monitor chassis. This manual includes, operating information, parts list and schematics among other information and is 053X0639001 / CT-8026 / CT8026 Wells Gardner 33″ U3000 Series P805 and other Series monitor Flyback transformer. Wells Gardner U2000 Series (25k2193) 25" and 27" inch monitor chassis New Aftermarket T700. 229-5375 Email: Click here to email us Service and repair your broken Wells Gardner part. Replaced both parts and the monitor now powers up. It was a wells Gardner k4600. I replaced the capacitors, reflowed solder on all header pins, and adj Wells Gardner K7000 Series 105C 100% Nichicon arcade monitor Cap Kit “Mega Deluxe Cap Kits” 21 Caps total and the kit includes the 3 Bi-Polar caps. Description. Not all kits contain every cap on the board. 23. 33” Digital Monitor 9500 W. If your board has been modified or previously repaired, this kit may not match your needs. An easier method to get the metal width coil tray out of the way that I’ve used was to mark one of the 2 width coil wires that solder to the posts with a Wells Gardner V1000 Series 19″ and 22″ Black and White Monitor Cap Kit 105C Nichicon Capacitors. Wells Gardner 39K7601 / M3976 / K7600 39″ Arcade Monitor Cap Kit 105C and 100% Nichicon capacitors. It ended up being either cold solder joints, bad cable connections or a simple reset Be the first to review “DNF-FA2019 Wells Gardner K7300 Series 19″ Monitor Flyback” Cancel reply. Frontage Road, Burr Ridge, IL 60527 Ph: 800. Striped trio spacings (standard): 0. Nov 18, 2006 · It's in a Wizard of Wor machine. Be sure to install all the parts on the monitor even though many of the original parts seem to be working fine. Wells Gardner U2000 Series (25k2193) arcade Monitor Cap Kit 105C 100% Nichicon Capacitors. New Wells-Gardner D9200 Monitor Review. Oct 30, 2020 · To learn some of my methods of troubleshooting and other general arcade tech stuff, or just to lend support to the channel, visit my Patreon page and at:http Wells Gardner D7700 arcade monitor Cap Kit 105C 100% Nichicon Capacitors “Mega Deluxe Cap Kits” and the Kit includes 46 Capacitors which includes 3 Bi-Polar caps. Wells Gardner D9200 / D9202 27″ & 33″ Series arcade Monitor Cap Kit 105C 100% Nichicon Capacitors. 15" Wells-Gardner 32" LCD monitor. to 28. The Wells-Gardner D9200 arcade monitor is a unique “all-in-one” solution to this dilemma. The new flyback has two red wires and the smaller diameter red wire goes to the single pin post on the neck board and the larger diameter red wire goes to the white Wells Gardner K7000 Series Flyback Transformer 053X0528-001 this works for the 13″, 19″ and 25″ standard resolution monitor chassis. Wells Gardner K7400 / K7500 Series arcade Monitor Cap Kit 105C 100% Nichicon Capacitors. Wells Gardner D9400 arcade monitor Cap Kit 105C 100% Nichicon Capacitors “Mega Deluxe Cap Kits” and the Kit includes 70 Capacitors which includes 6 Bi-Polar caps. It is now posted here: Wells Gardner U3100 14″ P786 arcade monitor Cap Kit 105C 100% Nichicon Capacitors “Mega Deluxe Cap Kits” and the Kit includes 47 Capacitors total which includes 4 Bi-Polar caps. I encourage using the Search feature and reading other threads on problems/fixes for the U2000 nuking a HOT. Symptom: Monitor powers up, but image is very streaky. 22 ea. This video will detail the repair of a Wells Gardner 19K7203 monitor. wells gardner k7500 p793 repair Wells Gardner k7400 k7500 u2000 u5000 Color Raster Monitor $140; Vector Monitor $175; LCD Monitor (Quote only and only onsite) Skip the repair line $50; Additional Cost: If your monitor requires a flyback, we charge a flat rate of $65 per flyback. yes no voltage regulator issue low +160 vdc you likely have a horizontal deflection failure. Kit contains caps, resistors, transistors, diodes and high voltage pot. Kit includes 18 - 105º Nichicon capacitors and installation instructions Jul 13, 2021 · Wells-Gardner K7806 13". “Mega Deluxe Cap Kits” BEST quality, low ESR longest life capacitors Repair Kits; Touch Screen Controllers WMS-A012506-00-00; Wells Gardner- WGF1990-TSLMO6F; 69951010; Screen Size . Complete, original Wells Gardner Quadrascan (6100) Color X-Y (aka vector) Display Service Monitor. com Or for just about the same price, you can get a brand new remote board assy from chad over at arcade cup (www. -Ian Jun 12, 2024 · If your D9200 is a different model than the 27D9202 this kit will not work for you! Part Number: Wells Gardner D9200 Cap Kit / Get Well Kit for Monitor Repair. The guy I bought the game from said he gets it to work by powering it down and then back on to match one of the clicks. 1358 1/2 West Broadway Missoula, MT 59802 United States of America Wells Gardner K4900/K5500 monitor cap kit. Wells Gardner P819 deflection & P826 neck PCB for 13″ and 19″ on the K7203, WGE1972-H0GS57L, WGE1972-H0GS39L, WGE1972-H0GS79L, and WGE1972-H0TS49A but verify your PCB number Description. com CHUCK RABIOLA SYMPTOM CAUSE COMMENTS NO VIDEO/PICTURE Q800, U500, D310, R310, T700 CHECK VIDEO INPUT CABLE DISTORTED VIDEO Q800, U701, U500, L701 ADJUST VR701 Jul 25, 2023 · I've got a MKII cabinet that's been sitting for about 10 years and just started working on it. Wells Gardner PD279400, PD279410, PD339400 and include the PS279401 SYNC INPUT BOARD and PN279400 / PN279410 / PN339400 VIDEO BOARD. Wells Gardner K4900 Series arcade monitor Cap Kit 105C 100% Nichicon capacitors. I didnt notice it until I was almost done editing. 14uH --> 125uH Found to be used in on wells k5515 medium rez 25" 4915 19" medium rez and k7000 medium rez monitor boards. Horizontal hold will barely lock and the picture is all If your arcade monitor has stopped functioning, or is partially functioning, I am currently able to repair the following makes/models monitors: Electrohome G07-CAO G07-CBO G07-CFO G07-FBO. Nov 25, 2007 · If you have the wells monitor with remote board that has broken pots, you can get pots from bob roberts(www. Wells Gardner U3100 14 inch with P786 (054A3101-013) main chassis and P831 (054A0831-001) Neck PCB. We can repair your Wells Gardner model 13K7801 in our facility. Pac-man, Galaga, StarGate, Defender or just about any other vintage video game. I couldn't get the raster adjusted in the center of the screen, there was a gap about 1 1/2" to 2" wide on the right side that was blank.  Kit includes:9 Capacitors6 Resistors1 Pot5 Diodes11 TransistorsCap Map. Wells Gardner P757 PCB for the K7201, 13K7201, 19K7200, WGM1372-M1TS30F, WGM1972-H0GS66H, WGE1372-HOTS82K, and WGE1972-H0GS39L but verify your PCB number because WG used Mar 13, 2011 · The # 69X0942-100 manual for Wells-Gardner models 19K4601, 4602, 4603, 4604, and 4653 has now been scanned and digitally cleaned up by me. Remove the junk electrolytic capacitors and install good brands like Nichicon. or Best Offer +$14. It's easier to get than the Amplifone. Need to do some troubleshooting and repair, but am having trouble identifying the monitor model. 1/2 Watt 25% Cermet TRIMMER POTENTIOMETER. If your board contains more, they are not included in this kit. After a lot of research I learned I have a dreaded 27" Wells Gardner D9200 monitor. I just did a cap kit, and nothing really changed. Wells gardner K4600 and K4700 – Set to 127vdc – Check with black meter lead on chassis ground and red lead on blue wire of the TR502. Arcade Parts and Repair, Inc. If you a have a Wells Gardner 25" or 27" monitor that needs repair, send us the chassis (and all connected components) and we'll repair and upgrade it back to new condition. This monitor is manufactured by Wells-Gardner’s Korea plant. “Mega Deluxe Cap Kits” 40 Caps total including the Bi-Polar capacitor. Sponsored. This kit will work for every model of standard resolution k4900 chassis and also the 19inch K5500 / K5501 standard resolution chassis including the 19K5603 chassis. When turned on it makes a faint clicking sound and does not display anything on the screen. 93 sold. We can repair your Wells Gardner model 19K7601 in our facility. Sure enough - it was open. 1 kHz. Part Aug 7, 2011 · Monitor works but it goes into shutdown after 5 minutes , b plus is at 183 volts. I may be able to repair others that are not on this list, Wells Gardner K7203 arcade monitor Cap Kit 105C 100% Nichicon Capacitors “Mega Deluxe Cap Kits” and the Kit includes 38 Capacitors which includes 4 Bi-Polar caps. -We include a 60 day warranty on all repairs we do. RECOMMENDED ITEMS: $7. Part # 49-1153-00 $ 21. 7 uf @ 160 volts (often found leaking, open, or damaged) TwistedQuarter. Like, share, and subscribe if you would like to. 30W so these are much higher rated than original and don’t buy those garbage kits that other vendors sell that have 0. Home; Help I suspect almost any electronics tech could repair one given this information. Additional information. If interested. January 24, 2025, 05:54:48 pm. 55th Street, Suite A z McCook, Illinois 60525-3605 z 708. A detailed Theory of Operation for the Wells-Gardner 19K6100 monitor is included here in Appendix C. Wells-Gardner # 088X0236-001. Use this to rebuild your vector monitor along with our LV-2K kit. Monitor Specifications Wells-Gardner 1. May 9, 2013 · The following guides were created by us for use with all 25″ and 27″ Wells Gardner arcade chassis models: U2000, U5000, k7400 and k7500. Used on monitor chassis such as GO7 X01, Sanyo 20EZV Q902, Wells Gardner K4900 (Q352), Wells Gardner K4800, Red Tent, Atari Disco monitor at Q902. Wells Gardner 19K4600 19K4900 19K7000 25k7000. New posts Search forums. BEST quality, low ESR, longest life capacitors. 053X0589-001 Wells Gardner K8000 Series 25" NOS factory Flybacks. the most common monitor problem. 0625 lbs: Dimensions: Arcade Parts and Repair, Inc. 1358 1/2 West 5775 Ten Mile Road, Warren, MI 48091 Tel: 800. Upon removing power, the screen flashes as the power fades. Ships By 01/13/2025. This is a HOT high output transistor for many different monitor chassis. This kit is for the V1001, 19V1001, 19V1002, 19V1003, 22V1001, and 22V1003 monitor chassis and for both P277 and P292 PCBs. This monitor can replace the old Nintendo Sanyo monitor since it can accept the inverted video from Donkey Kong & other Nintendo game boards of that era. Step 1 - Click the green button above to add the part and complete the RMA form. video arcade crt arcadecrt arcadecup arcade cup Chad Entringer wells gardner neotec flyback remote board parts chassis service queue form Fast turnaround flat rate. May sub on the K7201 for the 053X0641-001. 95 shipping. Sanyo EZ-20. Jun 12, 2024 · Part Number: Wells Gardner K4600 Cap Kit / Get Well Kit for Monitor Repair with Filter Cap. www. K4600 series (46xx). Part Number: 891-1311-16. com D9400/D9410 Series Wells-Gardner Electronics Corporation User Manual for D9400 D9410 Series Digital-Control Color Monitor Wells-Gardner Electronics 9500 W. CAPKIT INFORMATION: Neckboard: C204 4. Wells Gardner 19K6100 Series Color Vector Arcade Monitor Cap Kit 105C 100% Nichicon capacitors. This is the monitor used in many of Atari's color vector games including Tempest, Gravitar, Black Widow and Space Duel. Wells Gardner K7000 Arcade P802 / P632 Remote Adjustment PCB Trimmer Pot Kit. Aug 1, 1996 · Each monitor design has a slightly different electrical characteristic and tube shape that will cause games designed for use with the Amplifone to bulge out around the edges (a defect known as "barreling") when using a Wells-Gardner and similarly will cause games designed for use with the Wells-Gardner monitor to cleave inward around the outer Thanks for watching. Apr 3, 2015 · I have a Wells-Gardner monitor from a VR Vortex machine that I've identified as a D9200 montor. Step 2 - Print the RMA and put it in a box with the items for repair Oct 6, 2016 · Technical - Videogames - Monitors Official Wells Gardner D9200 Schematics and Troubleshooting Guide not matching? . $99. All of our Cap Kits / Get Well Kits include a sticker so you can place it on the monitor to help Used on Wells Gardner K7500 series monitor chassis. Mar 22, 2007 · A common fail point of the start-up circuit is R760. 42 $5. After rebuilding my 6100 for Tempest, I encountered this new issue where the you could see the full game, but it was in the lower right corner of the monitor. 55th Street Suite A Mc Cook, Il. Test with B&K rejuvenator CRT socket adapter CR-31 and set the heater voltage to 6. Happ Controls KJ-1915 & KJ-1315 & KJ-XX15 top Happ Controls KJ-1915 & KJ-1315 & KJ-XX15 bottom electrohome G07-CBO top electrohome G07-CBO bottom sharp-image-si-727r-ds-top sharp-image-si-727r-ds-bottom neotec-nt-2515c-top neotec-nt-2515c-bottom electrohome AC. No Neck Glow. 2100 z Fax 708. Jun 27, 2015 · Wells Gardner V1000 Series arcade Monitor C101 Multi Cap B+ Filter Can Kit 105C 100% Nichicon Capacitors. I looked on Wells Gardner's site and they have a cap kit for $10 (S-KIT CAP Jun 23, 2020 · The TPG was causing a high pitch squeal. The Wells-Gardner K7000 is among the most common and easiest to fix of their monitors. The chassis is made of sturdy materials and is designed to last for years, ensuring that you get the best value for your money. 5 kHz. Wells Gardner P736 & P828 monitor chassis 19K3001, 17K3004, & 17K3005. Never do we just fix the fault w/ the board, but instead do a complete service on the whole board. Age, humidity, and temperature will cause the value of electrolytic capacitors to Send us your Wells Gardner monitor U5000 "chassis", remote adjust boards, neck boards, and any associated cables. Pac-Man, Galaga, and More! BRAND NEW replacement monitor for your upright or cocktail table Pac-man or Ms. For parts or repair. Dec 12, 2011 · Just picked up a Need For Speed Underground with a 27" flat screen CRT Well Gardner. Wells Gardner K4600 Monitor Repair Cap Kit w/ FILTER CAP - 30 Years in Business. 053X0437-02 Flyback Transformer. Qty: $ 7. PO Box 455 Wells Gardner D9800 / D9810 (PD279810) Revision 4 arcade monitor Cap Kit 105C 100% Nichicon Capacitors “Mega Deluxe Cap Kits” and the Kit includes 56 Capacitors which includes 3 Bi-Polar caps. 00 Add to cart; Arcade Parts and Repair, Inc. “Mega Deluxe Cap Kits” Our kits have some of the BEST quality, low ESR, and longest life capacitors included. Brand New. 0W 066X0040-050 Z601 ZENER DIODE 12V 5% 0. and read through the D9200 Troubleshooting AC. Wells Gardner New aftermarket K6100 color vector flyback T900. Needs a cap kit, and has a few lifted or broken traces, missing solder pads, and a couple bridged solder pads. PO Box 455 “ Wells-Gardner Announces Business by E-Commerce, ” PR Newswire, August 16, 1999. arcade-cup. !!!!!THIS AUCTION IS FOR REPAIRING YOUR CIRCUIT BOARD!!!!!This auction is for the repair of a Wells Gardner D9200 chassis. in horizontal configurations there are 2 bolts to remove (roughly marked in image) and the metal tray slides to the right and lifts up and out. Monitor Flybacks 053X0589-001 Wells Gardner K8000 Series 25″ Flyback $ 55. Make offer or would trade for none working arcade or pinball projects. 00 fee for diagnosis and repairing of faulty circuit board. I checked one voltage, and it Wells Gardner 27 inch U2000 / K2000 Series (27k2391) (WGM2720) (P717N / P717-N) arcade Monitor Cap Kit 105C 100% Nichicon Capacitors. Wells Gardner K4800 Series arcade monitor Cap Kit 105C 100% Nichicon capacitors. If we can't fix it quick, we'll send it back at no charge to you. “ Wells-Gardner Announces $2 Million Intranet Order, ” PR Newswire, March 9, 1998. This kit is for the Wells Gardner WGZ1373, WGZ1973, K7301, K7302, 19K7302, 13K7301, 19K7300, and 13K7300 chassis. This monitor repair kit is designed for the Wells-Gardner 19K6100 X-Y color monitor, as used in Tempest, Space Duel, and other Atari color X-Y games. Though not as durable as its predecessor the K4900, the K7000 is one of the best monitors you can learn how to fix. Fixed: Game is restricted to the lower right corner of the Screen. Must include neck Wells-Gardner used absolute crap bottom-of-the-barrel capacitors which were barely good enough to even make a 90 day warranty period. Wells Gardner K4600 Chassis Dead Wells Gardner Monitor Chassis Identification - Model Dec 14, 2024 · Wells-Gardner K7806 13”. Requirements. Linearity: ±5% INPUT SIGNAL Video: RGB analog Wells Gardner D9200 / 27D9202 Cap Kit / Get Well Kit for Monitor Repair. $200 If interested. I’m interested in having you repair a newly acquired WGM2474-U4TS16Q Wells Gardner K7400 monitor. Position V. Qty: add to cart. HOTs don't just blow on their own though, I can't guarantee simply replacing it will fix your problem. therealbobroberts. A sincere advocator of the classical video arcade scene. Reject Bezel, Black Nylon for Wells gardner / Coin Controls. Can these be made reliable with aftermarket caps/components or are they just junk all together? Am I better off buying a Wells 7k chassis which are rock solid or have Buffet rebuild this chassis. Jan 30, 2024 · I've recently acquired a Big Buck Hunter II: Sportsman's Paradise and it has seen some action. com/MattymosArcadeMusicWhac-A-Mole by Jake WatersFree Downloadhttps://t a more in-depth guide to disassembly and service of the Wells-Gardner K4600. Monitor Repair Kit for Wells-Gardner D9400. 4 Capacitors included in the kit and with instructions. This kit includes the Neck PCB, one header, one connector and the new crimp pin. 69 delivery. A quick search of the connected parts found that Q708 was shorted. Mode 2: 24. 229-5350 | Fax: 800. “Mega Deluxe Cap Kits” 25 Capacitors including the Bi-Polar in this kit with great instructions. Wells-Gardner Game Pro 19" LCD Flat Screen Monitor - Drop-In Replacement for Pac-Man & Ms. “ Wells-Gardner Hits Europe, ” AB Europe, May 2000, p. The tube is a Philips MV A48ABK05X. Z Sep 26, 2019 · Inside is a Wells-Gardner 19K7201 monitor. Will sell together or tub and chassis separately. Jun 12, 2024 · Part Number:Wells Gardner K4900 Cap Kit / Get Well Kit for Monitor Repair. com Jan 13, 2025 · Monitor Repair Kit for Wells-Gardner D9400. Some people may mistakenly think this is a “K7000” monitor, but its actually a newer model with a very different chassis. Charts showing waveform diagrams and voltage checks at test points. 290. The monitor and machine have had quite a life, but the screen does work OK, save a small defect in the bottom right Wells Gardner 19v2000 Black and White X/Y vector monitor rebuild kit. If you are only going to have one monitor, I'd suggest the Wells Gardner 6100. May 26, 2012 · I just bought another Ms Pac/Galaga Reunion and the monitor has bad burn and jittery. The guy I got it from said the machine would turn on, but the monitor wouldn't work and crackles, pops, and sparks would shoot out of the back. com Wells Gardner 4900 Arcade Monitor Repair Service. Local pick up in Smithfield R. 99. Must be Wells Gardner brand u2000, u5000, k7400 or k7500 monitor chassis. Contains transistors, 105º Nichicon Capacitors and installation instructions. Wells Gardner K4700 Series arcade monitor Cap Kit 105C and 100% Nichicon Capacitors. dwuf kcrcw hhbtc wtoyup cwtbxy nrn wirhgsj eqkrlv glise imj